# What’s actually in a bottle of tattoo ink?

November 25, 2026 · https://tatbot.ai/updates/2026-11-25/

In a 2024 study of tattoo inks sold in the United States, chemists examined one blue ink whose label listed both a blue pigment and a white one. Their Raman spectrum contained the blue pigment’s characteristic pattern. A second instrument picked up titanium, evidence consistent with the white pigment listed on the label. Each test supplied a piece of the identification. The researchers could make sense of the pieces together because they knew what each instrument could measure. [Moseman and colleagues, figure 2](https://pmc.ncbi.nlm.nih.gov/articles/PMC11450547/).

That example captures a problem for anyone who wants to reproduce a tattooing result. A color name tells you what bottle to look for. Understanding what came out of it means asking about the pigment, the liquid that carries it, and how well those materials were identified.

## Pigment and carrier do different jobs

A conventional tattoo ink is usually a **suspension**. Solid particles are dispersed through a liquid, like fine sediment held in water. The carrier can also contain dissolved substances. This difference between suspended and dissolved material matters in a lab. An analysis of the liquid can reveal compounds that a measurement of the dried pigment misses. [Moseman and colleagues, experimental procedure](https://pmc.ncbi.nlm.nih.gov/articles/PMC11450547/).

The pigments create the color through the way they absorb and scatter light. White pigments can be part of a colored ink. The blue sample in the opening example listed **Pigment Blue 15**, a copper phthalocyanine pigment, and **Pigment White 6**, titanium dioxide. A bottle's name describes a finished shade, so different blends can sit under the same everyday color category. Researchers measuring particle sizes in 58 commercial inks also found substantial differences across their samples. A pigment name gives a chemical clue, while the size and aggregation of its particles need their own measurements. [Blue ink example](https://pmc.ncbi.nlm.nih.gov/articles/PMC11450547/) · [Høgsberg and colleagues, particle measurements](https://doi.org/10.1111/j.1365-2133.2011.10561.x).

The carrier gets the pigment from the bottle to the mark. In all 54 inks in the U.S. study, the researchers detected water and at least one of two alcohols, ethanol or isopropyl alcohol. They also found glycerol and other compounds in subsets of the samples. Additives can modify how readily a liquid flows, wets a surface or keeps particles dispersed. Finding a compound in a finished ink tells you it was detected. Determining what it contributes to that formulation takes a separate comparison. [Carrier measurements and discussion](https://pmc.ncbi.nlm.nih.gov/articles/PMC11450547/).

## How a lab reads the bottle

In **Raman spectroscopy**, an instrument measures light scattered by a sample. A small share of that light changes frequency as it interacts with molecular vibrations. Plot the shifts and you get a pattern that can be compared with spectra from known materials. Yakes and colleagues built a reference library from tattoo pigments. Their work also illustrates a practical constraint: the measurement conditions that reveal one pigment's pattern may work less well for another. [Yakes and colleagues, Raman reference measurements](https://doi.org/10.1002/jrs.5095).

The researchers used **X-ray fluorescence**, or XRF, to find which elements were present. X-rays excite atoms in the sample, and the energies of the X-rays the atoms emit are characteristic of particular elements. Copper and titanium appeared in the XRF spectrum of the blue ink. The Raman spectrum supported the blue copper-containing pigment. The titanium signal and label together supported the presence of titanium dioxide, whose Raman features were hard to see in that mixture. The elemental signal alone leaves open which titanium-containing compound supplied it. [Two measurements on the same blue ink, figure 2](https://pmc.ncbi.nlm.nih.gov/articles/PMC11450547/).

For the carrier, Moseman's team separated samples by centrifugation and distillation. They applied **nuclear magnetic resonance** spectroscopy, or NMR, to both the collected liquid and the residue. NMR detects how certain atomic nuclei respond in a magnetic field. The position and relationships of the signals give clues to a molecule's structure. The team collected selected fractions using liquid chromatography, then examined them with gas chromatography–mass spectrometry, or GC–MS, among other tests. The gas chromatography column separates compounds as they pass through it. The mass spectrometer records ions and fragments that help identify them. Each method brought a different part of a crowded mixture into view. [Carrier analysis methods](https://pmc.ncbi.nlm.nih.gov/articles/PMC11450547/).

The opening diagram is a guide to those overlapping measurements. A real analysis can split a sample several ways, compare it with reference materials and return to the same ingredient with a second technique. A credible result names the instrument, the material it measured and the basis for the identification.

## What the label survey found

Moseman and colleagues tested red, yellow, green, blue, white and black inks from each of nine brands commonly sold in the United States. **Forty-five of the 54 sampled inks had an unlisted pigment or additive.** The researchers counted three more as minor discrepancies, such as a different low-boiling alcohol or a listed component they could not detect. Six agreed with the declared ingredients within the scope of the analysis. These are results for the selected samples. The authors’ categories describe how the measurements and declarations differed. [U.S. ink study, discussion and figure 3](https://pmc.ncbi.nlm.nih.gov/articles/PMC11450547/).

The carrier accounted for many mismatches. The team found signals consistent with polyethylene glycol, or **PEG**, in 28 inks. They also found propylene glycol in 15 inks that omitted it from the label. PEG is a family of polymers, so the identification of its repeating structure supplies less information than a full measurement of chain lengths and concentration. These findings give researchers specific questions about formulation. Testing how much a particular additive changes the flow or deposited mark would require controlling the other ingredients. [Carrier results and NMR interpretation](https://pmc.ncbi.nlm.nih.gov/articles/PMC11450547/).

The Swiss survey by Niederer and colleagues asked a narrower question across more products. It screened for organic pigments in 396 tattoo inks and 55 permanent makeup inks collected from 2009 to 2017. The lab compared mass spectra against references and used complementary methods when it needed to resolve a difficult identification. Repeated findings of copper phthalocyanine pigments in this survey and in the U.S. samples give useful context for pigment choice. The two surveys sampled different markets and years and assessed different sets of ingredients. [Swiss pigment screening study](https://doi.org/10.12688/f1000research.13035.2) · [Comparison in the U.S. study](https://pmc.ncbi.nlm.nih.gov/articles/PMC11450547/).

## What “not detected” can mean

The **Colour Index** gives pigments standardized names such as Pigment Blue 15 and Pigment White 6. A name can still leave finer distinctions open. A follow-up study of blue and green inks described difficulty using Raman spectra to distinguish some **polymorphs** of Pigment Blue 15. In a polymorph, the same molecules pack into a different crystal arrangement. X-ray diffraction probes the repeating arrangement in a crystal and can supply information that the Raman measurement leaves unresolved. [Colour Index classification](https://colour-index.com/about) · [Moseman and colleagues, blue and green inks](https://doi.org/10.1039/D4AN00793J).

A report can also say that a compound was below the **detection limit**, the level at which a method can reliably distinguish its signal under the test conditions. In the U.S. study, glycerol was listed on 36 inks, while the researchers detected it in 29 inks overall. They noted that some glycerol signals may have been too weak to see with their NMR setup. Some other signals were strong enough to see but too ambiguous to assign. Presence, identity and concentration are three separate results. [U.S. ink study, carrier results and limitations](https://pmc.ncbi.nlm.nih.gov/articles/PMC11450547/).

Think of a hypothetical ink in which a small amount of yellow pigment sits beside a strongly scattering blue one. The yellow might be difficult to pick out of the mixture even when a reference sample gives a clear spectrum. Separating the pigments or measuring another property could help. A careful comparison between a bottle and its label tracks what the test found, how confidently the lab identified it, and which parts of the declaration remain unresolved.

## Ingredients, traces and living organisms

A formulation lists materials intended to perform a job. An elemental assay can also find constituents present at trace levels. For example, Wang and colleagues used inductively coupled plasma mass spectrometry to measure chromium and nickel in a survey of 73 inks, including purchased and previously opened samples. The instrument measures elemental content after sample preparation. Chromium can occur in different chemical forms, and the survey left those forms unresolved. [Wang and colleagues, analytical survey](https://doi.org/10.1111/cod.13913).

How much of an element is in a bottle and how much comes out of the material under given conditions are different measurements. In 2026, Astolfi and colleagues measured total elemental content after digesting samples. They also tested what could be extracted into water, saline and artificial sweat. The extractable fractions depended on the element, ink and liquid used. Those numbers describe the laboratory extractions. Measuring exposure from pigment deposited in living skin would require evidence from that setting. [Astolfi and colleagues, extraction and digestion study](https://doi.org/10.1002/ansa.70103).

A microbiology survey asks whether organisms can be recovered from the ink using specified growth conditions. In 2024, Yoon and colleagues cultured bacteria from 26 of 75 sealed tattoo and permanent makeup ink samples. Sixteen of the 49 samples labeled sterile yielded growth. Those counts belong to the sampled products and their test conditions. The study measured contamination in bottles. Estimating infection rates would require a study of tattoo recipients. A chemical ingredient analysis and a microbiological test answer different questions about the same product. [Yoon and colleagues, results and table 4](https://doi.org/10.1128/aem.00276-24).

## Making an ink comparison repeatable

A studio or robotics lab can start by recording the product name, shade, lot number when available and which bottle supplied the sample. A photo preserves the label as it appeared at the time of the test. If an artist mixes colors or dilutes an ink for a practice test, the mixture belongs in that record too. **A product name identifies what was ordered. A lot and bottle record identify what was used.** This matters even when a full chemical analysis is outside the scope of the work.

The earlier article on [the physics of tattooing](https://tatbot.ai/updates/2026-11-17/) follows the interaction of ink, needle and substrate. In experiments with moving needles in agarose, Oyarte Gálvez and colleagues observed different tracks across commercial permanent makeup inks and aqueous test liquids. Several properties changed together, including viscosity and adhesion. The experiments show why it is worth recording the material alongside tool motion, while leaving the influence of individual ingredients to a controlled comparison. [Moving-needle experiments, section III.C](https://arxiv.org/abs/1811.00510).

Suppose a robot starts making wider lines after a fresh bottle is opened. One test would repeat the same pattern on identical practice coupons using two identified bottles, varying the bottle order across repeats and keeping ink preparation, tool type, motion and imaging fixed. Each run would need a fresh ink supply to avoid carrying one sample into the next. Measuring the marks under the same lighting would test whether widths differed in that setup. Comparing multiple bottles per lot would help distinguish a difference between bottles from a difference between lots. Measurements of the fluid and pigment would be a follow-up if the marks diverged. This is a proposed bench test, and any result would describe the chosen practice material.

A record that links the mark back to the bottle gives the next person something to reproduce. It also gives them a place to look when the result changes, before they start adjusting the robot.
